4 – MIB-II Objects
59047-03 B 4-3
A
sysUpTime (1.3.6.1.2.1.1.3)
The time, in hundredths of a second, since the network management portion of
the system was last re-initialized.
Syntax
TimeTicks
Access
read-only
Status
mandatory
Return Value
The time since the switch was powered on, or last reset (reset, hardreset, or
hotreset) was executed. For example, 3 days 21 hours, 5 minutes, and 26.84
seconds. The value will roll over after approximately 497 days of continuous
up time.
sysContact (1.3.6.1.2.1.1.4)
The textual identification of the contact person for this managed Node, together
with information on how to contact this person.
Syntax
DisplayString (SIZE (0..255))
Access
read-write
Status
mandatory
Return Value
The default is: <sysContact undefined>. The string size is limited to a
maximum of 64.
Seitenansicht 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 251 252

Kommentare zu diesen Handbüchern